Fire Protection and Mechanical Equipment

Fire Protection Valves: Types, Functions and Selection

Explore the valve types used in sprinkler, hydrant and fire pump systems, their functions, typical locations and the key points for selecting them.

ORFA Technical TeamUpdated: Oct 30, 20264 min read
Fire protection valves used in fire suppression systems

In fire suppression systems, valves decide when, where and at what pressure water flows. An isolation valve left closed by mistake or an uncontrolled pressure rise can prevent the system from doing its job in a fire. Fire protection valves are valves specifically designed, and usually UL/FM approved, to shut off and direct flow, regulate pressure, prevent backflow and allow the system to be tested.

This article covers the main valve types used in fire protection installations, their functions and the key selection points.

Types of Fire Protection Valves

Butterfly Valve with Supervisory Switch

Used as a zone control and isolation valve. Its supervisory (tamper) switch reports the open/closed position to the fire alarm panel; if the valve is partially or fully closed, a fault signal appears at the panel. Its compact body makes it popular in tight spaces and large sizes.

OS&Y Rising Stem Valve

On an OS&Y (Outside Screw & Yoke) valve, the stem rises as the valve opens. The visible stem length shows at a glance, even from a distance, whether the valve is open. It is widely used on pump suction and discharge lines, main supply lines and zone inlets.

OS&Y Valve Supervisory Switch

Mounted on the yoke of an OS&Y valve, it senses the stem position and sends the open/closed status to the fire alarm panel, so the valve is monitored both visually and electrically.

Fire Check Valve

Allows flow in one direction only. At pump discharges, fire department connections and points where different water supplies meet, it prevents backflow and protects equipment and the water supply.

Pressure Reducing Valve

In high-rise buildings, on lower floors or wherever pump pressure is excessive, it reduces inlet pressure to the value allowed for system components and hydrant/hose valve outlets. This protects equipment from overpressure and gives a safe outlet pressure for hose use.

Pressure Relief Valve

Installed on the fire pump discharge, it releases excess water when system pressure exceeds its set point, protecting pipes and components. Under NFPA 20 it is required where the maximum pump discharge pressure could exceed the rating of system components. This applies especially to diesel engine-driven pumps (because of possible overspeed, about 121% of churn pressure plus suction pressure is considered) and to variable speed pumps. A relief valve is a safety device and must not be used to regulate pressure in normal operation.

Test and Drain Valve

Simulates the flow of a single sprinkler to test the alarm valve and flow switches, and drains the line during maintenance. It is usually combined with a sight glass to show flow.

Flow Meter (Fire Pump Test Meter)

Measures fire pump flow for periodic performance tests. With a flow meter on the pump test line, pressures are checked at churn, rated flow and 150% of rated flow. NFPA 20 requires the metering device to be capable of measuring at least 175% of the pump’s rated flow.

Valve Types at a Glance

ValveMain functionTypical location
Butterfly valve with supervisory switchIsolation, position monitoringZone inlets, mains
OS&Y valveIsolation, visual position indicationPump suction/discharge, main supply
Fire check valveBackflow preventionPump discharge, fire department connection
Pressure reducing valveLimiting outlet pressureLower zones of high-rise buildings, hydrant outlets
Pressure relief valveRelieving overpressureFire pump discharge
Test and drain valveAlarm test, drainingAlarm valve station, end of zones
Flow meterMeasuring pump flowPump test line

Selection Criteria

  • Material: Cast iron, ductile iron, brass/bronze or stainless steel, depending on water quality and environment.
  • Connection: Flanged, grooved or threaded, matching the piping system.
  • Pressure rating: Determined by pump churn pressure and static pressure.
  • Approvals: UL, FM or VdS approved products according to the project specification and insurer.
  • Supervision: The position of every isolation valve in the system must be monitorable.
Tip: An isolation valve left closed is one of the most critical faults in a fire protection system. After maintenance, always check that every valve is fully open and its supervisory switch shows normal at the panel.

Applications

  • Sprinkler systems
  • Hydrant and hose cabinet systems
  • Fire pump stations
  • Foam suppression systems

Frequently Asked Questions

Why are supervised valves used in fire protection systems?

A closed or partly closed valve stops water reaching the sprinklers in a fire. The supervisory switch continuously reports the valve position to the fire alarm panel and warns if it is closed by mistake.

Is a pressure relief valve the same as a pressure reducing valve?

No. A pressure reducing valve regulates outlet pressure during flow; a relief valve is a safety device that discharges water when pressure exceeds its set point.

What is a fire pump flow meter used for?

It measures flow during periodic pump performance tests, so you can verify that the pump delivers the required pressure at churn, rated flow and 150% of rated flow.

Conclusion

Fire protection valves keep a suppression system available, controllable and testable. Valves selected with the right type, pressure rating and approvals directly increase system reliability. Explore our products for water-based systems on the Water Fire Suppression Systems page.

Online Store

Buy fire valves online

Browse products on or-fa.com, our export store, see prices in USD and order online.

Buy Online →Request a QuoteAsk on WhatsApp

Technical support

Talk to our team to choose the right product.
+90 224 444 67 32[email protected]

Related Articles

Let’s choose the right product for your project

Buy from our online store or request a project-specific quotation.