Y-Type Strainers

Flanged Y-Type Strainers

Flanged Y-Type Strainers

Flanged Y-type strainers are filter fittings bolted between flanges ahead of equipment such as control valves, heat exchangers, pumps and meters on heating, cooling, steam and process lines, continuously holding back dirt on large-bore pipework. The screen chamber is closed by a bolted cover; cleaning is done by removing the cover.

Body material is chosen to suit the operating conditions: grey cast iron PN6 and PN16, ductile iron PN16 and PN25, cast steel PN25 and PN40, cast stainless PN16–PN40. Sizes start at DN15; cast steel bodies go up to DN500, with straight-through types from DN250 upwards. Face-to-face length follows EN 558 series 1, so the line dimension is kept with valves of the same size.

DN15–500size by body
PN6–PN40four body materials
0.25 mmfine screen option
450 °Cupper limit for cast steel

Main Applications

  • Central heating and cooling circuits
  • Steam distribution and condensate lines
  • Heat exchanger and control valve inlets
  • Cooling tower and chiller circuits
  • Stainless lines in chemical and food processes

Technical Data

ConnectionFlanged; EN 1092-1 / EN 1092-2
Face-to-faceEN 558 series 1: 130 mm (DN15) · 600 mm (DN200) · 1350 mm (DN500)
Grey cast ironPN6 / PN16, DN15–300, up to 300 °C
Ductile ironPN16 DN15–300, PN25 DN15–150, up to 350 °C
Cast steelPN25 / PN40, DN15–500, up to 450 °C
Cast stainlessPN16–PN40, DN15–200, up to 400 °C
Standard screen1 mm (DN15–50) · 1.25 mm (DN65–80) · 1.6 mm (DN100–300) · 3 mm (DN350–500)
Fine screen0.25 mm (DN15–300) · 0.8 mm (DN350–500)
Kvs (clean screen)6.9 (DN15) · 61 (DN50) · 234 (DN100) · 1873 m³/h (DN300)
Pressure at temperatureCast steel PN40: 23.8 bar at 400 °C
Screen reinforcementRing from DN50, support basket from DN150
Magnet optionBar magnet up to 450 °C, permanent magnet up to 210 °C

Material Options

PartPN16 · grey cast ironPN25 · ductile ironPN40 · cast steelPN40 · stainless
BodyEN-GJL-250 (EN-JL1040)EN-GJS-400-18U-LT (EN-JS1049)GP240GH+N (1.0619+N)GX5CrNiMo19-11-2 (1.4408)
CoverSame as bodySame as bodySame as bodySame as body
ScreenStainless steelStainless steelStainless steelStainless steel
Cover gasketDepending on modelDepending on modelDepending on modelDepending on model
Cover boltsDepending on modelDepending on modelDepending on modelStainless, depending on model
Drain plugOn the coverOn the coverOn the coverOn the cover

Selection note: Screen mesh is chosen according to the smallest passage in the protected equipment; since a fine screen increases pressure loss, it can be used during commissioning and then replaced with the standard screen. On large sizes, fitting a pressure gauge before and after the strainer allows screen blockage to be monitored by differential pressure.

Advantages

Line Length Match

  • EN 558 series 1 face-to-face.
  • Easy to place instead of or beside a valve.

Four Body Options

  • Grey iron, ductile iron, steel, stainless.
  • The right class for pressure and temperature.

High Kvs

  • 234 m³/h at DN100 with a clean screen.
  • Low pressure loss.

Reinforced Screen

  • Ring and basket on large sizes.
  • The screen does not collapse at high differential pressure.

Magnet Option

  • Catches iron particles separately.
  • Effective in condensate and closed circuits.

Construction and Design Features

  • Flanged Y body with angled screen chamber
  • Bolted cover with drain plug on the cover
  • Perforated cylindrical stainless screen
  • Reinforced screen design from DN50
  • Straight-through body option on large sizes

Send the size, pressure class, fluid, temperature and required screen mesh through the Request a Quote form; we will prepare the flanged strainer in the right body material.

How to Choose?

  1. Define pressure and temperatureIf the operating point exceeds 300 °C for grey iron or 350 °C for ductile iron, move to a steel body.
  2. Match size to the lineKeep the strainer size the same as the pipe and valve size.
  3. Choose screen meshSelect a standard or fine screen according to the narrowest passage in the protected device.
  4. Check pressure lossCalculate the loss with a clean and a dirty screen from the Kvs value.
  5. Leave maintenance spaceAllow room for the cover and screen to be pulled out during installation.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial installation equipment.
Technical ConsultancyWe help with body material, screen mesh and pressure loss selection.
Delivery from StockPN16 and PN25 flanged strainers are available from stock in DN15–DN200.
Spare PartsSpare screens, cover gaskets and other valve spare parts from a single source.
In This Group

Other Y-Type Strainers

Our Products

Our Flanged Y-Type Strainers

ORFA supplies flanged y-type strainers in a range of pressure classes, sizes and connection types to suit your application. Descriptions, technical specifications, materials and dimension tables are available on each detail page.

Get a quote for your project

Our sales team will prepare the best solution for your needs.