HVAC Valve Actuators

Linear Valve Actuators

Linear Valve Actuators

A linear valve actuator is an electric drive that moves the stem of a stroke (globe type) control valve up and down to open, close or position it proportionally.

It is used on fan coil, air handling unit, heat exchanger and heating circuit valves. The product range includes 300–800 N linear actuators, balancing valve actuators and electrothermal on-off actuators.

300 – 800 Nforce (depending on model)
20 mmstroke up to
0–10 Vmodulating control (depending on model)
IP54protection (linear actuator)

Main Applications

  • Fan coil valves
  • AHU heating-cooling valves
  • Heat exchanger control valves
  • Heating circuit mixing valves
  • Balancing valve control
  • Underfloor heating manifold valves

Technical Data

TypesLinear (stroke) actuator, electrothermal actuator
Linear actuator force300 N … 800 N (depending on model)
StrokeUp to 20 mm
SupplyAC 230 V · AC/DC 24 V
Control signal3-point · 0–10 V · 4–20 mA · Modbus RTU (depending on model)
Running time3-point 120 s or 30 s · modulating 30 s
Protection / ambientIP54 / −5 … +55 °C
Fluid temperature−25 … +130 °C
Electrothermal actuator100 N, NC or NO, two-position
Electrothermal power2.5 W (24 V model)

Material Options

PartLinear actuator · AC 230 VLinear actuator · AC/DC 24 VElectrothermal actuator
Control3-point0–10 V / 4–20 mATwo-position on-off
Force / stroke800 N / 20 mm800 N / 20 mm100 N / max. 4.5 mm
Running time120 s or 30 s30 sAbout 270 s
ProtectionIP54IP54Depending on model

Which material? Values come from the parent category manufacturer data. Actuator force must be chosen to meet the valve close-off pressure, and the actuator–valve adaptor fit must be checked.

Advantages

Precise Control

  • Proportional positioning

Wide Signal Choice

  • 3-point, 0–10 V, 4–20 mA

Quiet On-Off

  • Electrothermal type

Durable

  • IP54 housing

Construction and Design Features

  • Motor and gear mechanism
  • Connection to valve neck
  • Position indicator
  • Manual override (depending on model)

Send the valve type and size, control signal and supply; we will confirm a suitable linear valve actuator from stock.

How to Choose?

  1. Define the valveDetermine valve type, size and stroke.
  2. Calculate the forceChoose the force needed for the differential pressure.
  3. Choose the signalOn-off, 3-point or 0–10 V.
  4. Supply and adaptorCheck 230 V or 24 V and connection fit.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyTechnical support on actuator–valve compatibility and force selection.
Delivery from StockLinear and electrothermal valve actuators are shipped from stock.
Compatibility CheckChecked together with Proportional Control Valves for valve body fit.
In This Group

Other HVAC Valve Actuators

Get a quote for your project

Our sales team will prepare the best solution for your needs.