HVAC Valves

Linear Valves

Linear Valves

A linear valve is a stroke (globe type) control valve whose stem moves up and down; together with a valve actuator it sets flow proportionally or on-off in heating and cooling circuits.

It is used on fan coil, AHU, heat exchanger and heating circuits. The product range includes threaded 1/2″–1 1/4″ and flanged DN15–DN150, 2 and 3-way valves and fan coil valves.

1/2″ – DN150size (product range)
2 / 3-waytypes
PN16 / PN25pressure class (product names)
Motorisedwith linear actuator

Main Applications

  • Fan coil heating-cooling control
  • AHU coils
  • Heat exchanger primary circuits
  • Heating circuit mixing and diverting
  • District heating substations
  • Chilled water control

Technical Data

TypeStroke (linear) control valve
Ways2-way and 3-way (product range)
Threaded sizes1/2″, 3/4″, 1″, 1 1/4″ (product range)
Flanged sizesDN15 – DN150 (product range)
Pressure classPN16; PN10 / PN25 on some models (product names)
DriveLinear valve actuator
Characteristic / KvsDepending on model
Fluid and temperatureHeating-cooling water; depending on model

Material Options

Part2-way linear valve3-way linear valveFan coil valve
DutyThrottling flowMixing or divertingTerminal unit control
ConnectionThreaded or flangedThreaded or flangedThreaded
Size1/2″ – DN1501/2″ – DN1501/2″ – 1″
DriveLinear actuatorLinear actuatorElectrothermal or linear

Which material? When choosing a linear valve, Kvs value, valve authority and actuator close-off force should be assessed together. Pressure classes come from product names; Kvs and temperature are confirmed per model.

Advantages

Precise Flow Control

  • Modulating operation

2 / 3-Way

  • Throttling and mixing

Wide Size Range

  • From 1/2″ to DN150

Actuator Fit

  • With linear actuators

Construction and Design Features

  • Cast or brass body
  • Stroke stem and plug
  • Actuator connection neck
  • Threaded or flanged ends

Send the flow, differential pressure, connection type and actuator control; we will confirm a suitable linear valve and actuator.

How to Choose?

  1. Size and connectionDetermine the threaded or flanged size.
  2. Pressure classChoose PN for the system.
  3. Flow and temperatureSend flow and differential pressure for Kvs.
  4. DriveMatch an on-off or modulating actuator.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyTechnical support on linear valve Kvs and actuator selection.
Delivery from StockLinear HVAC valves are shipped from stock.
Compatibility CheckThe fit between linear valve and Electric Actuators is checked before ordering.
In This Group

Other HVAC Valves

Get a quote for your project

Our sales team will prepare the best solution for your needs.