Boiler Thermostats

A boiler thermostat is an immersion control device that senses water temperature with a rigid bulb in the boiler or calorifier pocket and switches the burner or pump at the set value.
It is used on central heating boilers, hot water calorifiers and high-temperature water circuits. The product range includes immersion boiler thermostats with 0/90 °C and 40/210 °C setting ranges.
Main Applications
- Heating boiler burner control
- Calorifier temperature control
- Circulation pump control
- High-temperature water circuits
- Hot water storage tanks
- Boiler control outside the panel
Technical Data
| Type | Immersion (boiler) thermostat |
|---|---|
| Setting ranges | 0/90 °C and 40/210 °C |
| Differential | 4 K ±1 (0/90 °C) · 9 K ±2 (40/210 °C) |
| Contact | SPDT, 10(2.5) A / 250 V |
| Rigid bulb | 7 × 8 mm; 50 / 100 / 200 mm length |
| Protection class | IP40 |
| Max. ambient temperature | 80 °C |
| Cable entry | M20 × 1.5 gland |
| Mounting | 1/2″ pocket |
Material Options
| Part | 0/90 °C type | 40/210 °C type |
|---|---|---|
| Differential | 4 K ±1 | 9 K ±2 |
| Typical use | Heating and hot water | High-temperature water and process |
| Contact | SPDT 10(2.5) A | SPDT 10(2.5) A |
| Bulb | 7 × 8 mm, brass sheath | 7 × 8 mm, brass sheath |
Which material? Values come from the boiler thermostat manufacturer sheet. A boiler thermostat is for operating control; a fixed-setting limit thermostat must also be used for over-temperature safety.
Advantages
Straight into the Boiler
- Mounted in a 1/2″ pocket
Two Ranges
- 0/90 and 40/210 °C
Strong Contact
- 10(2.5) A
Narrow Differential
- 4 K (0/90 type)
Construction and Design Features
- Rigid bulb with brass sheath
- Setting knob
- SPDT contact
- M20 cable gland
Send the setting range, bulb length and controlled device; we will confirm a suitable boiler thermostat from stock.
How to Choose?
- Pocket and bulbChoose a bulb length to suit the boiler pocket.
- AmbientCheck ambient does not exceed 80 °C.
- Setting rangeChoose 0/90 for heating, 40/210 °C for high-temperature water.
- Contact loadCompare burner or pump load with the contact rating.
Complementary Products
Why ORFA?
Other Thermostats

Frost Protection Thermostats
Frost protection thermostats protect air and water coils from freezing by reacting when temperature falls.
Details →
Capillary Thermostats
Capillary thermostats sense temperature through a capillary bulb and switch a contact at the set value.
Details →
Incubator Thermostats
Incubator thermostats keep the temperature in incubators steady and precise.
Details →
Surface Thermostats
Surface thermostats sense temperature through contact with a pipe or surface and switch a contact.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.