Level Control Devices

Electric Level Float Switches

Electric Level Float Switches

An electric float switch (cable float switch) hangs from its cable and tilts up and down with the liquid level, changing a contact inside the float to start and stop a pump. The free cable length between the fixing point and the float sets the operating range.

General-purpose and wastewater (sewage) models are available; the store range includes floats with PVC or rubber cables from 1.6 m to 10 m. Changeover contact models can be wired for both filling and emptying.

10 A / 250 Vcontact (datasheet)
IP68protection class
1.6 – 10 mcable length (product range)
10 barmax. pressure

Main Applications

  • Drainage and emptying with submersible pumps
  • Water tank filling control
  • Wastewater and septic pits
  • Rainwater and leak pits
  • Dry-run protection on booster tanks

Technical Data

Float bodyPolypropylene (PP)
CablePVC or rubber; 3×0.75 mm² or 3×1 mm² (by model)
Cable length1.6, 3, 5, 10 m (product range)
Operating voltage250 V AC, 50 Hz
Contact10 A – 250 V AC, NO / NC changeover
Protection classIP68
Operating temperature−25 °C … +60 °C
Max. pressure10 bar
Setting distanceUp to 750 mm
ModelsGeneral purpose, wastewater, pear type (product range)

Material Options

PartGeneral purposeWastewater model
FloatPPPP (by model)
CablePVC or rubberPVC or rubber
Contact10 A / 250 V ACBy model
UseClean water and tanksSewage and solids-laden liquids

Which material? A 10 A contact can run small single-phase pumps directly; larger and three-phase pumps must be connected through a contactor. For wastewater, choose the wastewater model that withstands solids.

Advantages

Direct Pump Control

  • No contactor on small pumps

Fully Sealed

  • IP68

Filling and Emptying

  • Changeover contact

Long Cable

  • Up to 10 m

Construction and Design Features

  • PP float body
  • Changeover switch inside
  • PVC or rubber cable
  • Cable weight or fixing clamp

Write the pump power, application (filling, emptying, wastewater) and cable length; we will confirm the right float switch.

How to Choose?

  1. Define the applicationChoose filling or emptying wiring.
  2. Select the modelUse the wastewater model in sewage.
  3. Set the cable lengthPick by the distance from panel to pit.
  4. Check the pump powerUse a contactor above 10 A.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyFloat switch model and cable length selection for your pump application.
Delivery from StockFloat switches with 1.6–10 m cable shipped from stock.
Pump MatchWe check the float contact against pump power.
In This Group

Other Level Control Devices

Alarm and Remote Monitoring Devices

Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.

Details →
Glass Tube Level Gauge

Glass Tube Level Gauge

Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.

Details →
Hydrostatic Level Transmitters

Hydrostatic Level Transmitters

Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.

Details →

Capacitive Level Sensors

Capacitive level sensors detect the level of liquids and solids by changes in capacitance.

Details →

Solids Level Switches

Solids level switches detect the level of powder and granular materials in silos and bunkers.

Details →
Boiler Proportional Level Controllers

Boiler Proportional Level Controllers

Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.

Details →
Boiler Level Switches

Boiler Level Switches

Boiler level switches detect low and high water levels in steam boilers and control the burner, pump or alarm.

Details →
Boiler Feed Water Level Controls

Boiler Feed Water Level Controls

Boiler feed water level controls start and stop the feed pump according to the water level in the steam boiler.

Details →
Magnetic Level Indicators

Magnetic Level Indicators

Magnetic level indicators show the tank level by transferring the movement of a magnetic float to external indicator flaps.

Details →
Magnetic Level Transmitter

Magnetic Level Transmitter

Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.

Details →
Stainless Steel Level Switch

Stainless Steel Level Switch

Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.

Details →
Plastic Level Switches

Plastic Level Switches

Plastic level switches are economical float switches used in water and mild chemical tanks.

Details →

Radar Level Transmitters

Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.

Details →
Reflex Glass Level Gauges

Reflex Glass Level Gauges

Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.

Details →
Level Indicators

Level Indicators

Level indicators allow the liquid level in tanks and vessels to be monitored on site.

Details →
Level Control Panels and Sensors

Level Control Panels and Sensors

Level control panels and sensors are control systems that automatically start and stop pumps according to the level in tanks and wells.

Details →
Liquid Level Electrodes

Liquid Level Electrodes

Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.

Details →
Float Level Switches

Float Level Switches

Float level switches change contact by means of a float moving with the liquid level and control a pump or alarm.

Details →

Float Valves

Float valves open when the water level in a tank drops and close when it is full, keeping the level mechanically.

Details →
Tank Level Switches

Tank Level Switches

Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.