Boiler Feed Water Level Controls

A boiler feed water level control is a mechanical level device that transfers the movement of a float in a chamber mounted beside the boiler to contact tubes, starting and stopping the feed pump. A stainless metal bellows between the float and the contact section transmits the movement without passing boiler pressure outside.
It is used on steam boilers, open and closed vessels and booster tanks. The store range includes devices with 1″ and DN25 chambers, single and double contact heads and a spare float.
Main Applications
- Steam boiler feed control
- Hot water and high-temperature water boilers
- Open and closed vessels
- Booster tanks
Technical Data
| Body | GGG 40.3 ductile iron |
|---|---|
| Float | Stainless steel |
| Sealing | Stainless metal bellows |
| Working pressure | 16 bar (float and bellows withstand 25 bar) |
| Medium temperature | Up to 200 °C |
| Contact | Mercury contact tubes; single or double contact (product range) |
| Level adjustment range | Wide type 15–75 mm, narrow type 15–30 mm |
| Connection | Flanged or threaded; 1″ and DN25 chamber models (product range) |
| Spare part | Spare float (product range) |
Material Options
| Part | Boiler feed level control |
|---|---|
| Body / chamber | GGG 40.3 ductile iron |
| Float | Stainless steel |
| Bellows | Stainless metal |
| Contact | Mercury contact tube |
Which material? The device is installed so its chamber stays level with the boiler and its steam and water connections remain open; if the chamber is not blown down regularly, sludge can affect the float.
Advantages
Mechanical Reliability
- No electronics needed
Pressure Resistance
- Bellows and float withstand 25 bar
Adjustable Range
- Wide or narrow type
Spare Parts
- Float and contact heads available separately
Construction and Design Features
- Ductile iron chamber connected to the boiler
- Stainless float inside the chamber
- Stainless metal bellows transmitting movement
- Head with mercury contact tubes
Write the boiler pressure, connection type and number of contacts; we will confirm the feed control with its spare parts.
How to Choose?
- Check the pressureConfirm boiler pressure is within 16 bar.
- Select the connectionChoose a 1″ threaded or DN25 flanged chamber.
- Set the number of contactsPick single or double contacts for pump and alarm.
- Choose the rangeSelect the wide or narrow adjustment range.
Complementary Products
Why ORFA?
Other Level Control Devices
Alarm and Remote Monitoring Devices
Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.
Details →
Glass Tube Level Gauge
Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.
Details →
Electric Level Float Switches
Electric level float switches float with the liquid level, change contact and operate a pump or alarm.
Details →
Hydrostatic Level Transmitters
Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.
Details →Capacitive Level Sensors
Capacitive level sensors detect the level of liquids and solids by changes in capacitance.
Details →Solids Level Switches
Solids level switches detect the level of powder and granular materials in silos and bunkers.
Details →
Boiler Proportional Level Controllers
Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.
Details →
Boiler Level Switches
Boiler level switches detect low and high water levels in steam boilers and control the burner, pump or alarm.
Details →
Magnetic Level Indicators
Magnetic level indicators show the tank level by transferring the movement of a magnetic float to external indicator flaps.
Details →
Magnetic Level Transmitter
Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.
Details →
Stainless Steel Level Switch
Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.
Details →
Plastic Level Switches
Plastic level switches are economical float switches used in water and mild chemical tanks.
Details →Radar Level Transmitters
Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.
Details →
Reflex Glass Level Gauges
Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.
Details →
Level Indicators
Level indicators allow the liquid level in tanks and vessels to be monitored on site.
Details →
Level Control Panels and Sensors
Level control panels and sensors are control systems that automatically start and stop pumps according to the level in tanks and wells.
Details →
Liquid Level Electrodes
Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.
Details →
Float Level Switches
Float level switches change contact by means of a float moving with the liquid level and control a pump or alarm.
Details →Float Valves
Float valves open when the water level in a tank drops and close when it is full, keeping the level mechanically.
Details →
Tank Level Switches
Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.