Level Control Devices

Float Valves

A float valve is a mechanical level valve fitted to a tank’s supply line that throttles the flow as the float rises and shuts the water off completely when the tank is full. It keeps the tank at the set level without electricity.

The store range includes plastic ball float valves from ½” to 2″. Stainless tank floats have an AISI 304 body and arm with an AISI 316 ball; with a 220 mm standard or 150 mm optional sphere they work up to 6 bar supply pressure.

½” – 2″size (product range)
6 barstandard supply pressure
90 °Cstainless type max.
No powermechanical closing

Main Applications

  • Roof and building water tanks
  • Livestock and irrigation tanks
  • Cooling tower basin make-up
  • Boiler feed water tanks
  • Process water break tanks

Technical Data

OperationValve throttled and closed by float movement
Plastic type sizes½”, ¾”, 1″, 1¼”, 1½”, 2″ (product range)
Stainless type materialBody and arm AISI 304, ball AISI 316; optional PTFE coating
Stainless type connection¾” or 1″ thread
Float diameter220 mm standard, 150 mm optional
Supply pressure6 bar standard; 8 bar with large float
TemperatureUp to 90 °C (stainless type)
MediumWater, demineralised water and neutral liquids
MountingHorizontal or vertical

Material Options

PartPlastic float valveStainless tank float
BodyPlastic (by model)AISI 304 stainless
ArmBy modelAISI 304 stainless
FloatPlastic ballAISI 316 ball, optional PTFE coating
UseClean water tanksHot water and neutral liquids

Which material? As supply pressure rises, more buoyancy is needed to close the valve; on lines above 6 bar use a large float or a pressure reducing valve.

Advantages

No Power Needed

  • Fully mechanical operation

Prevents Overflow

  • Water shut off when full

Wide Size Range

  • From ½” to 2″

Stainless Option

  • Resists hot water

Construction and Design Features

  • Valve body connected to the supply line
  • Closing arm linked to the float
  • Plastic or stainless spherical float
  • Horizontal or vertical mounting connection

Write the supply line size, pressure and water temperature; we will confirm a plastic or stainless float valve.

How to Choose?

  1. Set the sizeWrite the tank supply pipe diameter.
  2. Check the pressureUse a large float or pressure reducer above 6 bar.
  3. Choose the materialPrefer the stainless type for hot water and neutral liquids.
  4. Decide the orientationPick horizontal or vertical mounting by tank inlet.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyFloat valve size and material selection for tank supply.
Delivery from Stock½”–2″ float valves shipped from stock.
Compatibility CheckWe check the valve against your supply pressure.
In This Group

Other Level Control Devices

Alarm and Remote Monitoring Devices

Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.

Details →
Glass Tube Level Gauge

Glass Tube Level Gauge

Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.

Details →
Electric Level Float Switches

Electric Level Float Switches

Electric level float switches float with the liquid level, change contact and operate a pump or alarm.

Details →
Hydrostatic Level Transmitters

Hydrostatic Level Transmitters

Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.

Details →

Capacitive Level Sensors

Capacitive level sensors detect the level of liquids and solids by changes in capacitance.

Details →

Solids Level Switches

Solids level switches detect the level of powder and granular materials in silos and bunkers.

Details →
Boiler Proportional Level Controllers

Boiler Proportional Level Controllers

Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.

Details →
Boiler Level Switches

Boiler Level Switches

Boiler level switches detect low and high water levels in steam boilers and control the burner, pump or alarm.

Details →
Boiler Feed Water Level Controls

Boiler Feed Water Level Controls

Boiler feed water level controls start and stop the feed pump according to the water level in the steam boiler.

Details →
Magnetic Level Indicators

Magnetic Level Indicators

Magnetic level indicators show the tank level by transferring the movement of a magnetic float to external indicator flaps.

Details →
Magnetic Level Transmitter

Magnetic Level Transmitter

Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.

Details →
Stainless Steel Level Switch

Stainless Steel Level Switch

Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.

Details →
Plastic Level Switches

Plastic Level Switches

Plastic level switches are economical float switches used in water and mild chemical tanks.

Details →

Radar Level Transmitters

Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.

Details →
Reflex Glass Level Gauges

Reflex Glass Level Gauges

Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.

Details →
Level Indicators

Level Indicators

Level indicators allow the liquid level in tanks and vessels to be monitored on site.

Details →
Level Control Panels and Sensors

Level Control Panels and Sensors

Level control panels and sensors are control systems that automatically start and stop pumps according to the level in tanks and wells.

Details →
Liquid Level Electrodes

Liquid Level Electrodes

Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.

Details →
Float Level Switches

Float Level Switches

Float level switches change contact by means of a float moving with the liquid level and control a pump or alarm.

Details →
Tank Level Switches

Tank Level Switches

Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.