Boiler Level Switches

Boiler level switches monitor the water level in a steam boiler, start and stop the feed pump and raise an alarm when the level rises or falls dangerously. They are core elements of safe boiler operation.
Conductivity devices with 4 electrodes combine high level alarm, pump stop, pump start and low level alarm in one body and are used up to 32 bar and 238 °C. The store range also includes capacitive boiler level electrodes in 500–2000 mm lengths.
Main Applications
- Steam boilers
- Hot water boilers
- Feed water tanks
- Condensate collection tanks
Technical Data
| Measuring principle | Conductivity (4 electrodes) or capacitive |
|---|---|
| Functions | High alarm, pump stop, pump start, low alarm |
| Max. pressure | 32 bar |
| Max. temperature | 238 °C (saturated steam at 32 bar) |
| Connection | Flanged or threaded |
| Electrode head | Finned cooling tube |
| Electrode lengths | Cut to boiler levels; 500–2000 mm on capacitive type (product range) |
| Indicators | Low alarm, high alarm, pump run and stop lamps |
Material Options
| Part | Electrode device | Capacitive electrode |
|---|---|---|
| Sensing | 4 conductivity electrodes | Capacitive probe |
| Connection | Flanged or threaded | By model |
| Head | Finned cooling tube | By model |
| Length | Set by cutting | 500–2000 mm |
Which material? Boiler level switches do not replace low water safety; by regulation, independent low and high level alarm switches must also be fitted.
Advantages
4 Functions in One Body
- Alarm and pump control together
High Pressure
- Up to 32 bar
Cooled Head
- Electronics protected from heat
Visual Monitoring
- Status lamps
Construction and Design Features
- Electrode head with finned cooling tube
- 4 electrodes cut to boiler levels
- Flanged or threaded boiler connection
- Controller with status lamps
Send the boiler pressure and level points; we will define electrode lengths and the device for your boiler.
How to Choose?
- Set the boiler pressureCheck it stays within the 32 bar limit.
- Mark the level pointsTake alarm and pump points from the boiler drawing.
- Cut the electrodesSet each electrode length to its point.
- Complete the safetyAdd independent low and high level switches.
Complementary Products
Why ORFA?
Other Level Control Devices
Alarm and Remote Monitoring Devices
Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.
Details →
Glass Tube Level Gauge
Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.
Details →
Electric Level Float Switches
Electric level float switches float with the liquid level, change contact and operate a pump or alarm.
Details →
Hydrostatic Level Transmitters
Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.
Details →Capacitive Level Sensors
Capacitive level sensors detect the level of liquids and solids by changes in capacitance.
Details →Solids Level Switches
Solids level switches detect the level of powder and granular materials in silos and bunkers.
Details →
Boiler Proportional Level Controllers
Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.
Details →
Boiler Feed Water Level Controls
Boiler feed water level controls start and stop the feed pump according to the water level in the steam boiler.
Details →
Magnetic Level Indicators
Magnetic level indicators show the tank level by transferring the movement of a magnetic float to external indicator flaps.
Details →
Magnetic Level Transmitter
Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.
Details →
Stainless Steel Level Switch
Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.
Details →
Plastic Level Switches
Plastic level switches are economical float switches used in water and mild chemical tanks.
Details →Radar Level Transmitters
Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.
Details →
Reflex Glass Level Gauges
Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.
Details →
Level Indicators
Level indicators allow the liquid level in tanks and vessels to be monitored on site.
Details →
Level Control Panels and Sensors
Level control panels and sensors are control systems that automatically start and stop pumps according to the level in tanks and wells.
Details →
Liquid Level Electrodes
Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.
Details →
Float Level Switches
Float level switches change contact by means of a float moving with the liquid level and control a pump or alarm.
Details →Float Valves
Float valves open when the water level in a tank drops and close when it is full, keeping the level mechanically.
Details →
Tank Level Switches
Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.
Details →Get a quote for your project