Magnetic Level Indicators

A magnetic level indicator shows the level as a magnetic float, rising with the liquid in a chamber beside the tank, turns the red-and-white flaps outside. The indicator never touches the medium, giving clear remote reading without risk of glass breakage or gasket leaks.
Stainless standard series, lightweight thin type, PVC type for chemicals and boiler type for steam boilers are offered in stock lengths from 300 mm to 2000 mm. Adding a level switch and proportional transmitter enables pump and alarm control.
Main Applications
- Steam boilers (boiler type)
- Pressurised process tanks
- Fuel and water tanks (thin type)
- Acid and chemical tanks (PVC type)
- Condensate and feed water tanks
- Tall tanks needing remote reading
Technical Data
| Measuring principle | Magnetic float + red-and-white flap indicator |
|---|---|
| Chamber material | Stainless steel AISI 304 / 316 / 316L; PVC on PVC type |
| Float | Stainless AISI 316L (PN16, PN25, PN40 options) |
| Flaps | Aluminium (standard), plastic (thin type) |
| Pressure class | PN10 / PN16 / PN25, optional PN40; thin type max. 10 bar |
| Temperature | Up to 160 °C; 200 °C option (by model) |
| PVC type | DN20 PN6 flange, 6 bar (at room temperature), 70 °C |
| Stock lengths | 300, 500, 700, 1000, 1200, 1500, 2000 mm (product range) |
| Boiler type lengths | 310 – 900 mm, PN16 (product range) |
| Connection | Flange (DIN, ANSI, JIS), union, socket or nipple |
| Drain | 3/8″ plug; optional drain valve |
| Options | Level switch, proportional transmitter, level scale |
Material Options
| Part | Standard series | Thin type | PVC type |
|---|---|---|---|
| Chamber | Stainless AISI 304 / 316 / 316L | Stainless steel (by model) | PVC |
| Float | Stainless AISI 316L | Stainless steel | PVC |
| Flaps | Aluminium | Plastic | Aluminium |
| Pressure / temperature | Up to PN40 / 160 °C | 10 bar / 160 °C | 6 bar / 70 °C |
Which material? Standard series or boiler type are preferred on steam boilers and pressurised tanks, thin type on atmospheric fuel and water tanks, and PVC type for acid and alkaline solutions. The float is selected by medium density and operating pressure.
Advantages
Unbreakable Indicator
- Medium never touches the indicator
- No glass or gasket leak risk
Remote Reading
- Red-and-white flaps clearly visible
Automation Ready
- Switches and transmitters can be added
Four Series
- Stainless, thin, PVC, boiler type
Long Lengths
- Single piece up to about 6 m
Construction and Design Features
- Stainless or PVC chamber mounted beside the tank
- Magnetic float inside
- Red-and-white flap rail outside the chamber
- Flanged, threaded or union process connections
- Drain plug or valve at the bottom
Send the centre-to-centre distance, pressure-temperature and medium type; we will quote the right series and length with any switch and transmitter options.
How to Choose?
- Choose the seriesPick standard, thin, PVC or boiler type by pressure, temperature and medium.
- Measure the lengthTake the distance between the upper and lower tank connection centres.
- Select the connectionMatch the flange standard or threaded connection to the tank.
- Add automationPlan switches for pumps and alarms and a transmitter for remote monitoring.
Complementary Products
Why ORFA?
Other Level Control Devices
Alarm and Remote Monitoring Devices
Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.
Details →
Glass Tube Level Gauge
Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.
Details →
Electric Level Float Switches
Electric level float switches float with the liquid level, change contact and operate a pump or alarm.
Details →
Hydrostatic Level Transmitters
Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.
Details →Capacitive Level Sensors
Capacitive level sensors detect the level of liquids and solids by changes in capacitance.
Details →Solids Level Switches
Solids level switches detect the level of powder and granular materials in silos and bunkers.
Details →
Boiler Proportional Level Controllers
Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.
Details →
Boiler Level Switches
Boiler level switches detect low and high water levels in steam boilers and control the burner, pump or alarm.
Details →
Boiler Feed Water Level Controls
Boiler feed water level controls start and stop the feed pump according to the water level in the steam boiler.
Details →
Magnetic Level Transmitter
Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.
Details →
Stainless Steel Level Switch
Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.
Details →
Plastic Level Switches
Plastic level switches are economical float switches used in water and mild chemical tanks.
Details →Radar Level Transmitters
Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.
Details →
Reflex Glass Level Gauges
Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.
Details →
Level Indicators
Level indicators allow the liquid level in tanks and vessels to be monitored on site.
Details →
Level Control Panels and Sensors
Level control panels and sensors are control systems that automatically start and stop pumps according to the level in tanks and wells.
Details →
Liquid Level Electrodes
Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.
Details →
Float Level Switches
Float level switches change contact by means of a float moving with the liquid level and control a pump or alarm.
Details →Float Valves
Float valves open when the water level in a tank drops and close when it is full, keeping the level mechanically.
Details →
Tank Level Switches
Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.
Details →Get a quote for your project