Level Control Devices

Level Control Panels and Sensors

Level Control Panels and Sensors

Level control panels and sensors are auxiliary equipment that convert contact or analogue signals from level devices into pump, valve and alarm control. They let a magnetic indicator, electrode or switch be connected to an automatic fill-and-drain system.

The group includes reed-contact monostable and bistable switches, a two-relay control panel, a converter panel giving 4–20 mA or 0–10 V output, a liquid level relay with adjustable sensitivity and a time relay. Selection depends on the sensor output type and the load to be controlled.

2 relaysNO / COM / NC output
4–20 mAor 0–10 V output
250 V / 1 Aswitch contact rating
230 Vpanel supply

Main Applications

  • Pump control with switches on magnetic indicators
  • Level relays in electrode systems
  • Analogue level signal to SCADA and PLC
  • Fill-and-drain automation
  • Delayed pump control (time relay)

Technical Data

Switch typeReed contact, potential-free; monostable or bistable
Switch contact (AC)Max. 250 V / 1 A / 60 VA
Switch contact (DC)Max. 250 V / 0.5 A / 30 VA
Switch temperature−10 °C … +80 °C
Sensing elementPlastic (up to 80 °C) or metal (above 80 °C)
Two-relay panel230 V supply, about 3 W; 2 relays, NO / COM / NC
Proportional output4–20 mA or 0–10 V; 24 V DC supply
Liquid level relayAdjustable sensitivity, 110–230 V AC (product range)
Signal cable0.75 mm² shielded cable recommended

Material Options

PartFunction
Monostable switchChanges contact as the float passes, then returns
Bistable switchRemembers last position, suited to alarms
Two-relay panelStarts and stops a pump with two level points
Converter panelTurns level into a 4–20 mA or 0–10 V signal
Liquid level relayConverts electrode signal to relay output

Which material? Switch contacts are for low-power signals; loads such as pumps are controlled through the two-relay panel or a contactor. Shielded cable on analogue signal lines prevents interference.

Advantages

Ready Automation

  • Layer linking sensor to pump

Analogue Output

  • 4–20 mA and 0–10 V option

Flexible Control

  • Monostable and bistable switches

Delay Option

  • Stable control with a time relay

Construction and Design Features

  • Reed-contact switches fitted to indicators
  • DIN-rail relay and converter panels
  • Liquid level relay with electrode inputs
  • Shielded signal connections

Write the level device you use and the control required; we will choose the right switch, panel or relay together.

How to Choose?

  1. Identify the sensor outputClarify contact, electrode or analogue signal.
  2. Define the controlWrite pump, valve or alarm control.
  3. Select the deviceChoose a relay panel, converter or level relay.
  4. Plan the wiringUse shielded cable on analogue lines.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyPanel, relay and switch selection for level automation.
Delivery from StockSwitches, relays and panels shipped from stock.
Compatibility CheckWe match the panel to sensor output and the load to be controlled.
In This Group

Other Level Control Devices

Alarm and Remote Monitoring Devices

Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.

Details →
Glass Tube Level Gauge

Glass Tube Level Gauge

Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.

Details →
Electric Level Float Switches

Electric Level Float Switches

Electric level float switches float with the liquid level, change contact and operate a pump or alarm.

Details →
Hydrostatic Level Transmitters

Hydrostatic Level Transmitters

Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.

Details →

Capacitive Level Sensors

Capacitive level sensors detect the level of liquids and solids by changes in capacitance.

Details →

Solids Level Switches

Solids level switches detect the level of powder and granular materials in silos and bunkers.

Details →
Boiler Proportional Level Controllers

Boiler Proportional Level Controllers

Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.

Details →
Boiler Level Switches

Boiler Level Switches

Boiler level switches detect low and high water levels in steam boilers and control the burner, pump or alarm.

Details →
Boiler Feed Water Level Controls

Boiler Feed Water Level Controls

Boiler feed water level controls start and stop the feed pump according to the water level in the steam boiler.

Details →
Magnetic Level Indicators

Magnetic Level Indicators

Magnetic level indicators show the tank level by transferring the movement of a magnetic float to external indicator flaps.

Details →
Magnetic Level Transmitter

Magnetic Level Transmitter

Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.

Details →
Stainless Steel Level Switch

Stainless Steel Level Switch

Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.

Details →
Plastic Level Switches

Plastic Level Switches

Plastic level switches are economical float switches used in water and mild chemical tanks.

Details →

Radar Level Transmitters

Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.

Details →
Reflex Glass Level Gauges

Reflex Glass Level Gauges

Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.

Details →
Level Indicators

Level Indicators

Level indicators allow the liquid level in tanks and vessels to be monitored on site.

Details →
Liquid Level Electrodes

Liquid Level Electrodes

Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.

Details →
Float Level Switches

Float Level Switches

Float level switches change contact by means of a float moving with the liquid level and control a pump or alarm.

Details →

Float Valves

Float valves open when the water level in a tank drops and close when it is full, keeping the level mechanically.

Details →
Tank Level Switches

Tank Level Switches

Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.