Float Level Switches

A float level switch detects a level point when a magnetic float moving with the liquid operates a reed contact or microswitch. With its simple design and contact output it connects directly to pump, valve and alarm circuits.
Vertical and rod types entering from the tank top provide single or multi-point detection; rod types are made up to 6 m long with up to 6 NO or 2 NC contacts. Horizontal magnetic types mounted on the side wall work up to 150 °C and 16 bar.
Main Applications
- Water, fuel and chemical tanks
- Boiler feed and condensate tanks
- Hydraulic and lubricating oil tanks
- Wastewater and drainage pits
- Process tanks needing multi-point control
Technical Data
| Vertical type body-float | AISI 304; optional AISI 316 or PTFE coated |
|---|---|
| Vertical type temperature | −10 °C … +125 °C |
| Vertical type contact | NO / NC reed; max. 400 V, 60 VA / 1 A |
| Rod type | Flanged or BSP/NPT thread, up to 6 m, up to 6 NO or 2 NC contacts |
| Horizontal magnetic type | AISI 316L float, IP66, 150 °C, 16 bar |
| Horizontal type switch | 16 A microswitch, max. 480 V AC/DC |
| Pressure | Up to 16 bar (by model) |
| Min. liquid density | 0.8 g/cm³ (vertical), 0.6 g/cm³ (rod) |
| Protection class | IP68 (vertical), IP66 (horizontal) |
Material Options
| Part | Vertical / rod type | Horizontal magnetic type |
|---|---|---|
| Body / rod | AISI 304 (optional 316 or PTFE) | Cast aluminium housing |
| Float | AISI 304 / 316 | AISI 316L |
| Contact | Reed contact | 16 A microswitch |
| Connection | Threaded or flanged | Stainless or carbon steel flange |
Which material? Reed contact types are for low-power signals; high-current loads such as pumps must be driven through a relay or contactor. If the liquid density is below the float’s minimum, a different float is selected.
Advantages
Multi-Point Detection
- Several points in one rod body
High Pressure
- Up to 16 bar
Hot Media
- 150 °C on horizontal type
Easy Integration
- Contact output wired directly
Construction and Design Features
- Magnetic float
- Reed contacts inside the body or rod
- Cast housing with microswitch on horizontal type
- Threaded or flanged process connection
Write the tank mounting direction, number of points, pressure and temperature; we will define the right vertical, rod or horizontal switch.
How to Choose?
- Define the mountingChoose vertical or rod from the top, horizontal from the side.
- State the number of pointsConsider the rod type for several levels.
- Check the conditionsConfirm pressure, temperature and liquid density.
- Assess the loadDrive high-current loads from reed contacts through a relay.
Complementary Products
Why ORFA?
Other Level Control Devices
Alarm and Remote Monitoring Devices
Alarm and remote monitoring devices report the level status in tanks and wells by audible, visual or remote notification.
Details →
Glass Tube Level Gauge
Glass tube level gauges allow the liquid level inside a tank to be seen directly through a transparent glass tube.
Details →
Electric Level Float Switches
Electric level float switches float with the liquid level, change contact and operate a pump or alarm.
Details →
Hydrostatic Level Transmitters
Hydrostatic level transmitters measure level from the pressure of the liquid column and provide a continuous signal.
Details →Capacitive Level Sensors
Capacitive level sensors detect the level of liquids and solids by changes in capacitance.
Details →Solids Level Switches
Solids level switches detect the level of powder and granular materials in silos and bunkers.
Details →
Boiler Proportional Level Controllers
Boiler proportional level controllers continuously measure the water level in steam boilers and adjust the feed water proportionally.
Details →
Boiler Level Switches
Boiler level switches detect low and high water levels in steam boilers and control the burner, pump or alarm.
Details →
Boiler Feed Water Level Controls
Boiler feed water level controls start and stop the feed pump according to the water level in the steam boiler.
Details →
Magnetic Level Indicators
Magnetic level indicators show the tank level by transferring the movement of a magnetic float to external indicator flaps.
Details →
Magnetic Level Transmitter
Magnetic level transmitters convert the position of a magnetic float into a continuous electrical signal.
Details →
Stainless Steel Level Switch
Stainless steel level switches are float level switches with stainless steel bodies suitable for corrosive and hot liquids.
Details →
Plastic Level Switches
Plastic level switches are economical float switches used in water and mild chemical tanks.
Details →Radar Level Transmitters
Radar level transmitters measure the level of liquids and solids without contact and provide a continuous signal.
Details →
Reflex Glass Level Gauges
Reflex glass level gauges show the liquid level clearly in steam boilers and pressure vessels.
Details →
Level Indicators
Level indicators allow the liquid level in tanks and vessels to be monitored on site.
Details →
Level Control Panels and Sensors
Level control panels and sensors are control systems that automatically start and stop pumps according to the level in tanks and wells.
Details →
Liquid Level Electrodes
Liquid level electrodes detect the level of conductive liquids by electrode contact and send a signal to the level relay.
Details →Float Valves
Float valves open when the water level in a tank drops and close when it is full, keeping the level mechanically.
Details →
Tank Level Switches
Tank level switches signal at set levels in storage tanks to control filling, emptying and alarms.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.