Flow Switch

A flow switch is an electric switch that detects water flow in the line through a flexible vane reaching into the pipe through a drilled hole. When a sprinkler opens and water starts to flow, the vane bends with the flow and, after an adjustable delay, the switch sends an alarm to the fire panel.
The store range covers 2″, 2½” (76.1 mm), 3″, 4″, 5″, 6″ (165.1 / 168.3 mm) and 8″ pipe sizes. It is used at the inlet of each sprinkler zone, at floor control stations and on alarm valve outlets to tell the panel where the fire is.
Main Applications
- Sprinkler zone and floor inlets
- Floor control stations
- Alarm valve outlet lines
- Flow monitoring on hose cabinet supply lines
Technical Data
| Detection | Vane reaching into the pipe |
|---|---|
| Pipe size | 2″, 2½” (76.1 mm), 3″, 4″, 5″, 6″ (165.1 / 168.3 mm), 8″ (product range) |
| Mounting | Saddle body over a drilled hole |
| Delay | Adjustable (range by model) |
| Output | Dry contact (type by model) |
| Orientation | Horizontal or vertical flow-up line (by model) |
| Protection class | By model |
| Approval | UL / FM certificate by model |
Material Options
| Part | Flow switch |
|---|---|
| Housing | By model |
| Vane | Flexible, sized to pipe |
| Saddle and U-bolt | By model |
| Contact | By model |
Which material? The vane length is chosen by the pipe inside diameter; a wrong-size vane may rub the pipe or detect flow late. The delay is set to prevent false alarms from pressure surges.
Advantages
Zone Information
- Panel shows where the fire is
Against False Alarms
- Adjustable delay
Easy Installation
- Saddle mounted over a drilled hole
Wide Sizes
- From 2″ to 8″
Construction and Design Features
- Saddle body and U-bolt seated on the pipe
- Flexible vane reaching into the pipe
- Delay mechanism
- Contact block and cable entry
Write the zone pipe size and panel input type; we will confirm the right flow switch with stock details.
How to Choose?
- Set the pipe sizeWrite the pipe size and OD at the zone inlet.
- Pick the locationLeave enough straight pipe from valves and elbows.
- Adjust the delayChoose a delay that rides through pressure surges.
- Run the testFlow water through the test and drain valve and verify the panel signal.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.