Water Fire Suppression Systems

Flow Meters

Flow Meters

A fire flow meter is a measuring device connected to the fire pump test line that reads the pump flow directly. By running the pump at and above rated flow, you can check whether its pressure-flow curve meets the specification without discharging water.

The store range covers sizes from 2½” to 12″; the measuring range extends from 100 GPM (2½”) to 4500–5000 GPM (12″) depending on size. The meter is selected to cover the pump’s rated flow.

2½” – 12″size (product range)
100 – 5000GPM upper range
Pump testingperformance verification
Directflow reading

Main Applications

  • Periodic fire pump performance tests
  • Commissioning and acceptance tests
  • Pump test lines returning to the tank
  • Jockey and main pump flow checks

Technical Data

UseFire pump test line
Size and upper range2½” 100 · 3″ 200 · 4″ 450 · 5″ 500 GPM (product range)
6″ options500, 750, 1000, 1250 GPM (product range)
8″ options1500, 2000, 2500 GPM (product range)
10″ options3000, 3500, 4000 GPM (product range)
12″ options4500, 5000 GPM (product range)
ConnectionBy model
ReadingDirect flow indicator (by model)
InstallationStraight pipe runs at inlet and outlet (by model)

Material Options

PartFlow meter
BodyBy model
Measuring elementBy model
IndicatorBy model
ConnectionBy model

Which material? The meter should be selected to read up to about one and a half times the pump’s rated flow so the overload point can also be tested. For accurate readings, leave the straight pipe runs stated in the datasheet before and after the meter.

Advantages

Testing Without Waste

  • Test line can return to the tank

Direct Reading

  • Flow without extra calculation

Wide Range

  • From 100 GPM to 5000 GPM

Suited to Acceptance Tests

  • Pump curve verified on site

Construction and Design Features

  • Measuring body connected to the test line
  • Flow-sensing element
  • Flow indicator
  • Inlet and outlet connections

Send the pump’s rated flow and test line size; we will select a flow meter with the right range together.

How to Choose?

  1. Find the pump flowTake the rated flow from the pump nameplate.
  2. Set the rangeSelect a meter covering one and a half times rated flow.
  3. Match the sizePick the meter size for the test line diameter.
  4. Leave straight pipeApply the datasheet straight runs before and after the meter.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyFlow meter range and size selection for pump test lines.
Delivery from StockCommon flow meter sizes shipped from stock.
Pump MatchWe match the meter to the pump nameplate flow.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project