Water Fire Suppression Systems

Deluge Alarm System and Equipment

A deluge alarm system has all sprinklers or nozzles on the line open, and when triggered it discharges water over the entire protected area at once. The deluge valve is opened by a fire detector, a pilot sprinkler line or manual release.

The system consists of a deluge valve, solenoid or pilot trim, manual release station, alarm switches and open nozzles. It is used at transformer stations, fuel and chemical storage areas, aircraft hangars and other zones with fast-spreading fire risk.

Open nozzleswhole area at once
Detectoror pilot line release
Manual releaseemergency station
By modelsize and connection

Main Applications

  • Transformer and power stations
  • Fuel and chemical storage areas
  • Aircraft hangars
  • Cooling towers and conveyor lines
  • Production areas with fast fire spread

Technical Data

System typeOpen-nozzle deluge system
Main elementDeluge valve
ReleaseDetector + solenoid, pilot sprinkler line or manual
NozzlesOpen sprinklers or water spray nozzles
AlarmPressure switch and alarm gong
Foam optionUsable with foam concentrate (per project)
Size and connectionBy model (please ask)
ApprovalUL / FM / VdS certificate by model

Material Options

PartFunction
Deluge valveFeeds the whole line with water when released
Solenoid / pilot lineOpens the valve on the detector signal
Manual release stationOpens the valve by hand in an emergency
Open nozzlesDistribute water over the entire area
Alarm switchReports system operation to the panel

Which material? Because a deluge system wets the whole area at once, its water demand and pump capacity are higher than other systems; valve size and release method are defined together with the project calculation.

Advantages

Instant Full Coverage

  • Whole area wetted at once

Flexible Release

  • Detector, pilot line or manual

Cooling Effect

  • Reduces heat load on transformers and tanks

Foam Compatible

  • Can be combined with foam suppression

Construction and Design Features

  • Diaphragm or clapper deluge valve
  • Solenoid and pilot release circuit
  • Manual release and reset arrangement
  • Open-nozzle distribution line

Send the protected area, risk type and release method; we will work out the deluge station and nozzle list with your project team.

How to Choose?

  1. Define the hazardIdentify areas with fast spread or cooling needs.
  2. Choose the releasePlan detector, pilot line or manual release.
  3. Calculate water demandCompare the total flow of all nozzles with pump capacity.
  4. Consider foamEvaluate foam concentrate for flammable liquid areas.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyDeluge system component selection for high-hazard areas.
Delivery from StockValves and fittings used in the system shipped from stock.
Compatibility CheckWe plan the release trim to suit the fire alarm panel.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.