Water Fire Suppression Systems

NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

An NRS (non-rising stem) valve is a gate valve whose stem turns in place and moves the gate inside the body when the handwheel is turned. Because the stem does not rise, the valve height stays constant and it fits tight spaces under ceilings and in pits.

The store range includes DIN flanged models in DN100, DN125, DN150, DN200, DN250 and DN300. As its position cannot be seen from outside, in fire systems it is usually combined with a post indicator or tamper switch.

DN100 – DN300DIN flanged (product range)
Constantvalve height
Gate typefull bore
Indicator-readystem

Main Applications

  • Underground hydrant network valves
  • Sectional valves used with post indicators
  • Under-ceiling and tight-space installations
  • Pump room isolation valves
  • Water tank outlet lines

Technical Data

TypeNon-rising stem gate valve (NRS)
SizeDN100, DN125, DN150, DN200, DN250, DN300 (product range)
ConnectionDIN flanged (product range)
Pressure classBy model (confirmed with flange PN class)
BodyBy model (confirmed with manufacturer data)
StemInside the body, non-rising
OperationHandwheel or post indicator connection (by model)
Position monitoringWith tamper switch (supplied separately)

Material Options

PartNRS valve
BodyBy model
GateBy model
StemNon-rising type (material by model)
EndDIN flange

Which material? No reliable manufacturer datasheet was found for this valve; sizes are taken from store products, and material and pressure rating are confirmed by model.

Advantages

Constant Height

  • Stem does not protrude
  • Fits tight spaces

Suited to Buried Use

  • Operated from grade with a post indicator

Full Bore

  • Gate clears the flow when open

Large Sizes

  • Up to DN300

Construction and Design Features

  • Non-rising stem turning inside the body
  • Gate travelling along the stem
  • DIN flanged ends
  • Stem top suited to handwheel or indicator

Write the DN size and operation method (handwheel or post indicator); we will quote the NRS valve with the right accessory.

How to Choose?

  1. Define the locationChoose a post indicator for buried valves and a handwheel in open areas.
  2. Select the sizePick the line size from DN100–DN300.
  3. Check the flange standardMatch the DIN flange PN class with the mating flange.
  4. Plan position monitoringAdd a tamper switch or indicator.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyNRS valve selection for buried and tight-space applications.
Delivery from StockDN100–DN300 NRS valves in stock shipped immediately.
Compatibility CheckWe check the valve against the mating flange and indicator connection.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.