Water Fire Suppression Systems

Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

A butterfly valve with a monitoring switch combines a disc that opens and closes the fire line with a quarter turn and a switch that senses the valve position in one body. When the valve leaves the fully open position, the switch signals the fire alarm panel, so an accidentally closed zone does not go unnoticed.

Wafer type is available in 2″–12″, grooved ends in 1¼”–12″ and threaded type in 1″–5″, with 73 mm and 76.1 mm pipe options for 2½” lines. It is used for sprinkler zone control, in pump rooms and at alarm valve stations.

300 psipressure class (manufacturer catalogue)
1″ – 12″wafer, grooved, threaded
120 °Cmax. temperature
Monitoringposition switch

Main Applications

  • Sprinkler zone control valves
  • Wet and dry alarm valve stations
  • Fire pump suction and discharge lines
  • Hose cabinet and hydrant main supply lines
  • Riser and floor isolation points
  • Zone isolation during system maintenance

Technical Data

Connection typeWafer, grooved ends, threaded
Wafer sizes2″, 2½”, 3″, 4″, 5″, 6″, 8″, 10″, 12″ (product range)
Grooved sizes1¼”, 1½”, 2″, 2½” (73 / 76.1 mm), 4″, 6″ (165.1 mm), 8″, 10″, 12″ (product range)
Threaded sizes1″, 1¼”, 1½”, 2″, 2½” (73 / 76.1 mm), 3″, 5″ (product range)
Pressure class170 psi – 300 psi; 300 psi on wafer series (manufacturer catalogue)
Max. temperature120 °C (manufacturer catalogue)
BodyDuctile iron, ASTM A536 (manufacturer catalogue)
DiscNickel-plated ductile iron, ASTM A395 (manufacturer catalogue)
StemStainless steel, AISI 416 (manufacturer catalogue)
SealEPDM (manufacturer catalogue)
OperatorGear operator with handwheel (by model)
Monitoring switchSignals when leaving open position; contact type by model

Material Options

PartWafer typeGrooved endsThreaded type
BodyDuctile iron ASTM A536Ductile iron ASTM A536By model
DiscNi-plated ductile iron ASTM A395Ni-plated ductile iron ASTM A395By model
StemStainless steel AISI 416Stainless steel AISI 416Stainless steel (by model)
Seal / seatEPDMEPDMEPDM (by model)
ConnectionBetween flangesWith grooved couplingsFemale thread

Which material? Values are taken from the manufacturer’s fire protection catalogue; materials for the threaded type are not listed separately, so they are confirmed by model. For projects requiring UL/FM approval, the model certificate is supplied with the order.

Advantages

Closed Valve Alert

  • Position change reported to the panel
  • Less risk of a zone left closed

Fast Operation

  • Quarter-turn disc movement
  • Controlled closing with gear handwheel

Three Connection Options

  • Wafer, grooved and threaded bodies

Compact Body

  • Shorter than a gate valve

High Pressure Class

  • Up to 300 psi catalogue rating

Construction and Design Features

  • Ductile iron body and nickel-plated disc
  • AISI 416 stainless steel stem
  • EPDM-lined seat
  • Gear operator and handwheel with position indicator
  • Monitoring switch integrated in the gearbox

Send the pipe size, connection type (wafer, grooved, threaded) and the panel’s contact requirement; we will confirm the monitoring butterfly valve with stock details.

How to Choose?

  1. Choose the connectionUse wafer on flanged lines, grooved ends on grooved lines and threaded models on small sizes.
  2. Confirm the sizeOn 2½” lines check whether the pipe OD is 73 mm or 76.1 mm.
  3. Set the pressure classPrefer the 300 psi class that covers the pump shut-off pressure.
  4. Plan the panel wiringMatch the switch contact type with the fire alarm panel.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancySelection of monitoring butterfly valves and connection types for sprinkler zones.
Delivery from StockCommon wafer and grooved sizes shipped from stock.
Compatibility CheckWe check the valve size against the pipe OD on your line.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.