Fire Sprinklers

A fire sprinkler is an automatic suppression head whose glass bulb breaks when the ambient temperature reaches its rating, opening the head and spreading water over the protected area through its deflector. Only the sprinklers at the fire open; the rest stay closed.
Pendent, upright, sidewall and concealed types are offered with 68 °C, 79 °C and 93 °C ratings and 5 mm standard or 3 mm quick response bulbs. ELO and ESFR types for high-rack storage and escutcheons that cover the mounting gap are in the same group.
Main Applications
- Office, hotel and residential ceilings
- Shopping malls and car parks
- Production and workshop areas
- Rack storage (ELO, ESFR)
- Wall mounting in corridors and rooms
- Concealed mounting in decorative ceilings
Technical Data
| Operation | Glass bulb breaks with heat |
|---|---|
| Temperature rating | 68 °C, 79 °C, 93 °C (product range) |
| Storage type ratings | ELO 68–141 °C; ESFR 74 and 96 °C (product range) |
| Bulb colour code | 68 °C red, 79 °C yellow, 93 °C green, 141 °C blue |
| Response | Standard (5 mm bulb), quick (3 mm bulb) |
| Mounting type | Pendent, upright, sidewall, concealed |
| Connection | ½” (NPT on sidewall type); ELO and ESFR ¾” (product range) |
| Finish | White painted, brass, chrome plated (product range) |
| K-factor | By model |
| Accessory | ½” and ¾” escutcheon (white, chrome) |
Material Options
| Part | Brass | Chrome plated | White painted |
|---|---|---|---|
| Body | Brass | Chrome-plated brass (by model) | Painted brass (by model) |
| Bulb | Liquid-filled glass | Liquid-filled glass | Liquid-filled glass |
| Appearance | Natural metal | Bright chrome | Matches white ceilings |
| Typical use | Plant rooms, car parks | Decorative ceilings | Office and residential ceilings |
Which material? The temperature rating is chosen above the highest ambient temperature under the ceiling; 68 °C is used in normal spaces and 79 °C or 93 °C under hot ceilings and in plant rooms. K-factor and approval certificate are confirmed for the selected model.
Advantages
Localised Suppression
- Only the sprinkler above the fire opens
- Water damage stays limited
Quick Response Option
- Early opening with a 3 mm bulb
Wide Type Range
- Pendent, upright, sidewall, concealed
Storage Solutions
- ELO and ESFR for high racks
Aesthetic Choice
- Concealed type and chrome finish
Construction and Design Features
- Threaded body and water outlet
- Colour-coded glass bulb by temperature
- Deflector that spreads the water
- Frame and seal holding the bulb in place
Write the mounting type, temperature rating, response and finish; we will prepare the sprinkler and escutcheon list with stock details.
How to Choose?
- Choose the mounting typeUse pendent below suspended ceilings, upright on open ceilings and sidewall in corridors.
- Set the temperature ratingPick a rating above the ceiling ambient temperature.
- Decide the responseConsider quick response 3 mm bulbs in homes and offices.
- Select finish and escutcheonAdd a finish and escutcheon that match the ceiling.
Complementary Products
Why ORFA?
Types of Fire Sprinklers

Storage Sprinklers
Storage sprinklers are automatic fire sprinklers designed to protect high-piled storage areas.
Details →
Extended Coverage Sprinklers
Extended coverage sprinklers are automatic fire sprinklers that protect a larger area than standard sprinklers.
Details →
Dry Sprinklers
Dry sprinklers are automatic fire sprinklers used in areas at risk of freezing, with no water standing in the body.
Details →
Standard Coverage Sprinklers
Standard coverage sprinklers are automatic fire sprinklers widely used in general areas.
Details →Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project