Water Fire Suppression Systems

Above Ground Fire Hydrants

Above Ground Fire Hydrants

An above ground fire hydrant is an outdoor outlet connected to the buried fire water network, where firefighters and site teams connect hoses to draw water. The body stands above grade and the valve is operated from the top bonnet.

The store range has DN100 PN16 flanged hydrants in 130, 170, 215 and 245 cm lengths, plus a DN100 PN16 hydrant elbow for the network connection. The length is chosen by the burial depth of the network pipe.

DN100connection (product range)
PN16flange class
130 – 245 cmlength options
ElbowDN100 PN16

Main Applications

  • Industrial site hydrant networks
  • Housing estate and campus fire mains
  • Around warehouses and logistics areas
  • Car parks and open storage yards
  • Municipal and industrial zone connections

Technical Data

TypeAbove ground fire hydrant
ConnectionDN100, PN16 flange (product range)
Length130, 170, 215, 245 cm (product range)
FittingDN100 PN16 hydrant elbow (product range)
OperationFrom the top bonnet (by model)
OutletsNumber and coupling type by model
DrainBody drain arrangement (by model)
MaterialBy model

Material Options

PartHydrantHydrant elbow
BodyBy modelBy model
ConnectionDN100 PN16 flangeDN100 PN16 flange
Length130–245 cm—
UseAbove-grade outletTurn from main to hydrant

Which material? The hydrant length is chosen by the burial depth between the top of the network pipe and grade; in areas with freezing risk a self-draining body is recommended.

Advantages

Quick Access

  • Above grade and easy to find

Four Lengths

  • From 130 cm to 245 cm

Standard Connection

  • DN100 PN16 flange

Complete Set

  • Hydrant and elbow together

Construction and Design Features

  • Above-grade hydrant body and outlets
  • Valve operation at the top bonnet
  • DN100 PN16 flange at the base
  • Hydrant elbow connecting to the main

Write the burial depth and number of hydrants; we will quote hydrants of the right length with their elbows.

How to Choose?

  1. Measure the burial depthFind the distance between the main and grade.
  2. Choose the lengthPick from 130, 170, 215 or 245 cm.
  3. Add the elbowPlan a DN100 PN16 elbow for each hydrant.
  4. Plan the isolation valveFit an isolation valve before the hydrant.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyHydrant length and connection selection for site networks.
Delivery from StockDN100 PN16 hydrants and elbows shipped from stock.
Compatibility CheckWe define the hydrant length from your network depth.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.