Water Fire Suppression Systems

Fire Check Valve

Fire Check Valve

A fire check valve lets water flow in one direction only and stops the line draining back when the pump stops or mains pressure drops. In the dual plate wafer type, two spring-loaded half discs open with the flow and close quickly under spring force when it stops.

The store range includes dual plate wafer models in 2″, 2½”, 3″, 4″, 6″, 8″, 10″ and 12″; the manufacturer catalogue gives 2″–12″ sizes and 175–300 psi pressure classes for check valves. It is clamped between two flanges with bolts.

2″ – 12″size (manufacturer catalogue)
175–300 psipressure class
Dual platespring closing
Wafershort face-to-face

Main Applications

  • Fire pump discharge lines
  • Jockey pump outlets
  • Mains and tank connection points
  • Sprinkler supply risers
  • Fire department connection inlets

Technical Data

TypeDual plate, spring closing, wafer
Size2″, 2½”, 3″, 4″, 6″, 8″, 10″, 12″ (product range)
Pressure class175 psi – 300 psi (manufacturer catalogue)
InstallationBetween two flanges, with studs
OrientationHorizontal or vertical flow-up (by model)
BodyBy model
Plates and springBy model
SealingBy model (EPDM common)

Material Options

PartDual plate wafer check valve
BodyBy model
PlatesBy model
SpringStainless steel (by model)
SealingBy model

Which material? The catalogue gives sizes and pressure classes for the check valve family but does not list part materials; material data is confirmed for the selected model.

Advantages

Fast Closing

  • Spring action reduces water hammer

Short Length

  • Wafer body takes little space

Lightweight

  • Lighter than a swing check valve

Flexible Installation

  • Horizontal and vertical lines

Construction and Design Features

  • Thin wafer body fitting between flanges
  • Two half plates hinged at the centre
  • Stainless spring closing the plates
  • Sealing gasket on the seat

Send the line size and flange standard; we will quote the fire check valve with the stud set.

How to Choose?

  1. Set the sizeChoose the check valve for the pump outlet size.
  2. Check the pressure classSelect the class that covers the pump shut-off pressure.
  3. Plan the orientationObserve the flow arrow and vertical installation limits.
  4. Add the studsAdd the stud and nut set for wafer mounting.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyFire check valve size and class selection for pump outlets.
Delivery from Stock2″–12″ dual plate wafer check valves shipped from stock.
Compatibility CheckWe check the valve against the mating flange standard.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.