Fire Check Valve

A fire check valve lets water flow in one direction only and stops the line draining back when the pump stops or mains pressure drops. In the dual plate wafer type, two spring-loaded half discs open with the flow and close quickly under spring force when it stops.
The store range includes dual plate wafer models in 2″, 2½”, 3″, 4″, 6″, 8″, 10″ and 12″; the manufacturer catalogue gives 2″–12″ sizes and 175–300 psi pressure classes for check valves. It is clamped between two flanges with bolts.
Main Applications
- Fire pump discharge lines
- Jockey pump outlets
- Mains and tank connection points
- Sprinkler supply risers
- Fire department connection inlets
Technical Data
| Type | Dual plate, spring closing, wafer |
|---|---|
| Size | 2″, 2½”, 3″, 4″, 6″, 8″, 10″, 12″ (product range) |
| Pressure class | 175 psi – 300 psi (manufacturer catalogue) |
| Installation | Between two flanges, with studs |
| Orientation | Horizontal or vertical flow-up (by model) |
| Body | By model |
| Plates and spring | By model |
| Sealing | By model (EPDM common) |
Material Options
| Part | Dual plate wafer check valve |
|---|---|
| Body | By model |
| Plates | By model |
| Spring | Stainless steel (by model) |
| Sealing | By model |
Which material? The catalogue gives sizes and pressure classes for the check valve family but does not list part materials; material data is confirmed for the selected model.
Advantages
Fast Closing
- Spring action reduces water hammer
Short Length
- Wafer body takes little space
Lightweight
- Lighter than a swing check valve
Flexible Installation
- Horizontal and vertical lines
Construction and Design Features
- Thin wafer body fitting between flanges
- Two half plates hinged at the centre
- Stainless spring closing the plates
- Sealing gasket on the seat
Send the line size and flange standard; we will quote the fire check valve with the stud set.
How to Choose?
- Set the sizeChoose the check valve for the pump outlet size.
- Check the pressure classSelect the class that covers the pump shut-off pressure.
- Plan the orientationObserve the flow arrow and vertical installation limits.
- Add the studsAdd the stud and nut set for wafer mounting.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project