Fire Valves

The fire valves on this page are DIN flanged swing check valves used to prevent backflow in fire systems. The disc opens in the flow direction and closes onto its seat under its own weight and reverse pressure when the flow stops.
The store range includes models marked 300 psi and PN16 in 2″, 2½”, 3″, 4″, 5″, 6″, 8″, 10″ and 12″. They are preferred at fire pump outlets, tank connections and hydrant mains as large, low-loss backflow preventers.
Main Applications
- Fire pump discharge lines
- Fire water tank connections
- Hydrant mains
- Fire department connection lines
- Large riser inlets
Technical Data
| Type | Swing check valve |
|---|---|
| Size | 2″, 2½”, 3″, 4″, 5″, 6″, 8″, 10″, 12″ (product range) |
| Pressure class | 300 psi (product range; catalogue gives 175–300 psi for check valves) |
| Connection | DIN flanged, PN16 drilling (product range) |
| Orientation | Horizontal or vertical flow-up (by model) |
| Body | By model |
| Disc | By model |
| Sealing | By model |
Material Options
| Part | Swing check valve |
|---|---|
| Body | By model |
| Cover | By model |
| Disc | By model |
| Connection | DIN flange PN16 |
Which material? Size, 300 psi and PN16 values are taken from store product names; part materials are confirmed for the selected model. Where a short face-to-face is needed, a dual plate wafer check valve can be preferred.
Advantages
Low Pressure Loss
- Disc keeps the flow path open
Large Sizes
- Up to 12″
Standard Flange
- DIN PN16 drilling
Easy Maintenance
- Internals reached by opening the cover (by model)
Construction and Design Features
- Flanged cast body and bolted cover
- Disc swinging on a hinge pin
- Sealing on the seat
- Flow direction arrow on the body
Send the line size and flange standard; we will quote the swing check valve with gaskets and bolt set.
How to Choose?
- Set the sizeChoose the check valve for the line size.
- Confirm the flangeCheck that the mating flange is DIN PN16.
- Plan the orientationObserve the flow arrow and vertical installation limit.
- Assess the spaceConsider a wafer check valve if a short length is needed.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.