Post Indicator

A post indicator is a stem extension used to operate a fire valve that is buried or behind a wall from above, with a window showing whether the valve is OPEN or SHUT. The valve position is read without going down into a pit.
The store has two models: vertical (ground) and horizontal (wall) types. They are used on hydrant network sectional valves, the main fire valve at building entries and together with buried NRS valves.
Main Applications
- Underground hydrant network sectional valves
- Main fire valve at building entry
- Control valves behind walls
- Fire water tank outlet valves
Technical Data
| Type | Vertical (ground) and horizontal (wall) post indicator (product range) |
|---|---|
| Indicator | OPEN / SHUT position window |
| Compatible valve | Non-rising stem (NRS) fire valve |
| Operation | Lever or key (by model) |
| Length | Adjusted to burial depth (by model) |
| Locking | Lockable handle (by model) |
| Supervision | Tamper switch can be fitted (by model) |
| Material | By model |
Material Options
| Part | Vertical type | Wall type |
|---|---|---|
| Body | By model | By model |
| Stem extension | By burial depth | By wall thickness |
| Indicator | OPEN / SHUT window | OPEN / SHUT window |
| Operation | Handle (by model) | Handle (by model) |
Which material? No reliable manufacturer datasheet was found for the post indicator; models are taken from store products. Length is chosen by the valve burial depth and must be stated with the order.
Advantages
Remote Operation
- Valve opened and closed without entering a pit
Clear Position Reading
- Read through the OPEN / SHUT window
Secure Locking
- Lockable against unauthorised closure (by model)
Two Mounting Types
- Ground and wall installation
Construction and Design Features
- Extension stem connected to the valve stem
- OPEN / SHUT window showing the position
- Operating handle
- Ground or wall mounting body
Send the valve burial depth or wall thickness; we will confirm a post indicator of the right length.
How to Choose?
- Choose the mounting typeUse vertical in open areas and wall type on building facades.
- Measure the lengthFind the distance between grade and the valve stem.
- Check valve compatibilityConfirm the stem end fits the NRS valve.
- Plan supervisionAdd a tamper switch if required.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project