Preaction Systems

In a preaction system the sprinkler pipes are normally dry or filled with low-pressure air; water enters the pipes only when a fire detector alarms and the preaction valve opens. This prevents water from discharging on its own from a broken sprinkler or damaged pipe.
In the single interlock type the detector signal is enough; the double interlock type needs both a detector signal and the air pressure drop of an opened sprinkler. It is used in data centres, archives, museums, server and control rooms where accidental water discharge would cause severe damage.
Main Applications
- Data centres and server rooms
- Archives and libraries
- Museums and art storage
- Control and telecom rooms
- Sensitive storage in cold areas
Technical Data
| System type | Preaction sprinkler |
|---|---|
| Main element | Preaction valve |
| Interlock | Single or double interlock |
| Release | Fire detector + solenoid |
| Pipe content | Dry or low-pressure supervisory air |
| Alarm | Pressure switch and alarm gong |
| Size and connection | By model (please ask) |
| Approval | UL / FM / VdS certificate by model |
Material Options
| Part | Function |
|---|---|
| Preaction valve | Admits water to the pipes after detector confirmation |
| Solenoid | Releases the valve on the panel signal |
| Supervisory air | Monitors pipe tightness |
| Manual release | Provides manual triggering in an emergency |
| Alarm switches | Report low air and water flow |
Which material? A double interlock system gives the same freeze protection as a dry system while lowering the risk of accidental discharge; type selection and fire panel integration are done with the project team.
Advantages
Against Accidental Discharge
- No water from a broken sprinkler
Pipe Supervision
- Leaks monitored by air pressure
Early Warning
- Detector alarm comes before water
Freeze Protection
- Pipes can be kept dry
Construction and Design Features
- Preaction valve with solenoid release
- Supervisory air pressure trim
- Manual release and reset arrangement
- Alarm switches wired to the fire panel
Send the protected volume, interlock type and fire panel used; we will define the preaction station components together.
How to Choose?
- Assess damage riskChoose preaction where accidental discharge is critical.
- Set the interlock typeConsider double interlock for higher security.
- Plan panel integrationClarify detector and solenoid wiring.
- Select supervisory airPlan a compressor or nitrogen supply.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.