Water Fire Suppression Systems

Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

A fire system pressure reducing valve holds the outlet pressure at the set value however high the inlet pressure is. In tall buildings it prevents the pump pressure from being too high for sprinklers and hose cabinets on the lower floors.

The store range includes grooved-end models in PN20 class in 2″, 2½”, 3″, 4″, 6″ and 8″. They are used at floor and zone inlets, on hose cabinet feed arms and on risers divided into pressure zones.

PN20pressure class (product range)
2″ – 8″grooved ends
Adjustableoutlet pressure
Floor / zonepressure control

Main Applications

  • Lower-floor zone inlets in tall buildings
  • Hose cabinet feed arms
  • Risers divided into pressure zones
  • Inlets with high mains pressure

Technical Data

FunctionKeeping outlet pressure constant
Pressure classPN20 (product range)
ConnectionGrooved ends (product range)
Size2″, 2½”, 3″, 4″, 6″, 8″ (product range)
Outlet pressureAdjustable (range by model)
ControlPilot operated (by model)
GaugesInlet and outlet gauge ports (by model)
MaterialBy model

Material Options

PartPressure reducing valve
BodyBy model
DiaphragmBy model
Pilot circuitBy model
ConnectionGrooved end

Which material? Size and PN20 class are taken from store products; the outlet pressure range and materials are confirmed for the selected model. A strainer at the valve inlet is recommended.

Advantages

Constant Outlet Pressure

  • Outlet stays steady even if inlet fluctuates

Equipment Protection

  • Sprinklers and cabinets protected from overpressure

Grooved Installation

  • Fast coupling connection

Zone Control

  • Each zone set separately

Construction and Design Features

  • Main valve and pilot control circuit
  • Diaphragm sensing outlet pressure
  • Grooved inlet and outlet ends
  • Gauge connection points (by model)

Write the inlet pressure, required outlet pressure and line size; we will define the right pressure reducing valve.

How to Choose?

  1. Define the pressuresWrite the inlet and required outlet pressure.
  2. Select the sizeChoose the valve size for the zone flow.
  3. Add a strainerPlan a Y-strainer at the valve inlet.
  4. Plan setting and testingVerify the outlet pressure with a gauge at commissioning.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyPressure reducing valve selection for pressure zones.
Delivery from StockPN20 grooved pressure reducing valves in stock shipped immediately.
Compatibility CheckWe define the right size from inlet and outlet pressures with you.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Test and Drain Valve

Test and Drain Valve

Test and drain valves allow flow testing and draining of sprinkler lines.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.