Water Fire Suppression Systems

Test and Drain Valve

Test and Drain Valve

A test and drain valve combines an orificed test line that simulates the flow of a single sprinkler with a drain line that empties the zone in one body. Turning the handle to test proves that the flow switch and alarm system work.

According to the manufacturer catalogue it comes in 1″–2″, 300 psi class, with threaded or grooved ends. The store offers K57, K80, K200 and K360 orifices; the orifice is chosen by the K-factor of the smallest sprinkler in the zone.

1″ – 2″threaded or grooved
300 psipressure class (manufacturer catalogue)
K57 – K360orifice options
Test + drainin one body

Main Applications

  • Sprinkler zone flow tests
  • Flow switch and alarm checks
  • Zone draining and maintenance
  • Floor and riser test stations
  • Commissioning tests of fire lines

Technical Data

FunctionTest (orificed) and drain, single handle
Size1″, 1¼”, 1½”, 2″ (product range)
ConnectionThreaded or grooved (manufacturer catalogue)
Pressure class300 psi (manufacturer catalogue)
Orifice K-factorK57, K80, K200, K360 (product range)
PositionsOff, test, drain
Sight glassFlow sight glass (by model)
BodyBy model

Material Options

PartThreaded typeGrooved type
BodyBy modelBy model
ConnectionFemale threadCoupling groove
OrificeBy K-factorBy K-factor
SealingBy modelBy model

Which material? The orifice is matched to the smallest K-factor sprinkler in the zone, so the test realistically simulates the opening of a single sprinkler.

Advantages

Two Jobs, One Valve

  • Test and drain in the same body

Realistic Test

  • Orifice simulates a single sprinkler flow

Visual Check

  • Flow visible through a sight glass (by model)

Easy Maintenance

  • Zone drained from one point

Construction and Design Features

  • Single handle with three positions (off, test, drain)
  • Interchangeable orifice
  • Threaded or grooved inlet and outlet
  • Sight window to watch the flow (by model)

Write the zone pipe size and sprinkler K-factor; we will confirm the right orificed test and drain valve.

How to Choose?

  1. Set the zone sizeWrite the pipe size at the test point.
  2. Choose the K-factorBase it on the smallest sprinkler K in the zone.
  3. Select the connectionUse grooved on grooved lines and threaded on threaded lines.
  4. Plan the drain lineConnect the outlet to a visible drain.

Complementary Products

Why ORFA?

Since 1985Over 40 years of experience in supplying industrial piping equipment.
Technical ConsultancyOrifice K-factor and valve size selection for zone tests.
Delivery from StockCommon K80 and K57 orificed valves shipped from stock.
Compatibility CheckWe confirm the orifice against the sprinkler type in the zone.
In This Group

Other Water Fire Suppression Systems

Flow Switch

Flow Switch

Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.

Details →
Flow Meters

Flow Meters

Flow meters measure the flow delivered by the fire pump on pump test lines.

Details →
Pressure Relief Valve

Pressure Relief Valve

Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.

Details →

Deluge Alarm System and Equipment

Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.

Details →

Wet Alarm Valve System and Equipment

Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.

Details →
Fire Department Suction Connection

Fire Department Suction Connection

Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.

Details →
Fire Department Inlet Connection

Fire Department Inlet Connection

Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.

Details →
Butterfly Valve with Limit Switch

Butterfly Valve with Limit Switch

Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.

Details →

Dry Alarm Valve System and Equipment

Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.

Details →
NRS Non-Rising Stem Valve

NRS Non-Rising Stem Valve

NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.

Details →
NRS Valve Supervisory Switch

NRS Valve Supervisory Switch

NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.

Details →
OS&Y Rising Stem Valve

OS&Y Rising Stem Valve

OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.

Details →

OS&Y Valve Supervisory Switch

OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.

Details →
Preaction Systems

Preaction Systems

Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.

Details →
Post Indicator

Post Indicator

Post indicators allow underground fire line valves to be operated from above ground and show their position.

Details →
Waste Cone

Waste Cone

Waste cones direct water from test and drain lines to the drain in a visible way.

Details →
Fire Check Valve

Fire Check Valve

Fire check valves are approved check valves that prevent backflow in fire protection installations.

Details →
Fire Hose Cabinets

Fire Hose Cabinets

Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.

Details →
Fire Systems Pressure Reducing Valve

Fire Systems Pressure Reducing Valve

Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.

Details →
Fire Sprinklers

Fire Sprinklers

Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.

Details →
Fire Valves

Fire Valves

Fire valves are approved valves used to open and shut off lines in fire protection installations.

Details →
Above Ground Fire Hydrants

Above Ground Fire Hydrants

Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.

Details →
Grooved Pipe Fittings

Grooved Pipe Fittings

Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.

Details →

Get a quote for your project

Our sales team will prepare the best solution for your needs.