Fire Department Inlet Connection

A fire department inlet connection is installed on the building facade or a boundary wall and lets a fire engine pump water into the sprinkler or fire riser line inside. Each inlet has a check valve to prevent backflow and a capped quick coupling.
It is used when the fire tank or pump is insufficient, or as the only water source in buildings with dry risers. The number of inlets, coupling size and body type (wall or pillar) are set by the local fire brigade specification.
Main Applications
- External supply to sprinkler systems
- Water inlet for dry riser buildings
- Backup when the fire tank is insufficient
- Car park and mall facade connections
Technical Data
| Function | Fire engine pumping water into the system |
|---|---|
| Location | Building facade or boundary wall |
| Number of inlets | Two or more (by model) |
| Backflow prevention | Check valve on each inlet |
| Coupling | Storz-type quick coupling (size by model) |
| Body type | Wall type or pillar (by model) |
| Drain | Automatic drain (by model) |
| Material | By model |
Material Options
| Part | Inlet connection |
|---|---|
| Body | By model |
| Check valves | By model |
| Couplings | By model |
| Caps | By model |
Which material? As this product is not listed in the store, the number of inlets, coupling size and body type are defined with you according to the local fire brigade specification; an additional check valve on the connecting line is recommended.
Advantages
External Supply
- Fire brigade feeds the system directly
Backflow Protection
- Check valves at the inlets
Multiple Inlets
- High flow with several hoses
Visible Location
- Easy to find on the facade
Construction and Design Features
- Multi-inlet connection body
- Check valve on each inlet
- Capped quick coupling heads
- Outlet to the internal line
Write the system to be fed, number of inlets and the fire brigade coupling size; we will define the inlet connection with you.
How to Choose?
- Define the system to feedClarify sprinkler, dry riser or both.
- Choose the number of inletsSet the inlet count from the required brigade flow.
- Confirm the coupling sizeFollow the local fire brigade hose coupling.
- Plan the locationPick a facade point suited to fire engine access.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Hose Cabinets
Fire hose cabinets house the hose, nozzle and valve together and are used for first response in buildings.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.