Fire Hose Cabinets

A fire hose cabinet stores a valve, hose and nozzle connected to the fire water line together for first response in buildings and sites. When the door is opened and the valve turned, the hose is laid out and water is directed at the fire with the nozzle.
The store range has field-type cabinets with DN50 and DN65 valves, 20 m or 30 m hose and nozzle, in single or double sets; there is also a valved surface-mounted cabinet measuring 70 × 70 × 23 cm with 30 m hose.
Main Applications
- Industrial site protection (field type)
- Warehouses and logistics areas
- Car parks and open storage yards
- Building corridors and floor halls (surface type)
- Workshops and production areas
Technical Data
| Types | Field type, surface-mounted (product range) |
|---|---|
| Valve size | DN50, DN65 (product range) |
| Hose length | 20 m, 30 m (product range) |
| Number of sets | Single or 2 sets (field type) |
| Nozzle | Supplied with the hose (product range) |
| Surface cabinet size | 70 × 70 × 23 cm, with 30 m hose (product range) |
| Hose type | By model |
| Cabinet material | By model |
Material Options
| Part | Field cabinet | Surface cabinet |
|---|---|---|
| Cabinet | By model | By model (70 × 70 × 23 cm) |
| Valve | DN50 or DN65 | Valved (size by model) |
| Hose | 20 or 30 m | 30 m |
| Nozzle | Included | By model |
Which material? Hose length and cabinet layout are planned so that every point of the protected area can be reached by hose; DN65 options are preferred on site applications that need higher flow.
Advantages
Ready Set
- Valve, hose and nozzle together
Double Set Option
- Two hoses at once on site
Two Valve Sizes
- DN50 and DN65
Indoor and Outdoor
- Field and surface-mounted types
Construction and Design Features
- Cabinet with door
- Valve connected to the fire line
- Folded or reeled fire hose
- Nozzle at the hose end
Write the cabinet type, valve size, hose length and number of sets; we will quote the cabinets with stock details.
How to Choose?
- Define the locationChoose field type outdoors and surface-mounted indoors.
- Select the valve sizePick DN50 or DN65 by the required flow.
- Choose the hose lengthCalculate a length that reaches every point.
- Set the number of setsConsider double-set cabinets on large sites.
Complementary Products
Why ORFA?
Other Water Fire Suppression Systems

Flow Switch
Flow switches send a signal to the alarm panel when water starts flowing in the sprinkler line, indicating a fire.
Details →
Flow Meters
Flow meters measure the flow delivered by the fire pump on pump test lines.
Details →
Pressure Relief Valve
Pressure relief valves protect the installation by discharging excess water when overpressure occurs in fire pump systems.
Details →Deluge Alarm System and Equipment
Deluge alarm systems supply water simultaneously to open sprinkler or nozzle lines upon a detection signal.
Details →Wet Alarm Valve System and Equipment
Wet alarm valve systems are the main control valve and equipment that raise an alarm when a sprinkler opens in water-filled sprinkler lines.
Details →
Fire Department Suction Connection
Fire department suction connections are connection points that allow fire trucks to draw water from a reservoir or installation.
Details →
Fire Department Inlet Connection
Fire department inlet connections allow fire trucks to pump water into the building fire installation from outside.
Details →
Butterfly Valve with Limit Switch
Butterfly valves with limit switch report the valve position to the alarm panel in fire protection lines.
Details →Dry Alarm Valve System and Equipment
Dry alarm valve systems are valves and equipment controlling sprinkler lines filled with pressurized air in areas at risk of freezing.
Details →
NRS Non-Rising Stem Valve
NRS non-rising stem valves are fire line gate valves whose stem does not rise, suitable for limited spaces.
Details →
NRS Valve Supervisory Switch
NRS valve supervisory switches report the open or closed position of non-rising stem valves to the fire alarm panel.
Details →
OS&Y Rising Stem Valve
OS&Y rising stem valves are fire line gate valves whose open or closed position can be seen from the stem.
Details →OS&Y Valve Supervisory Switch
OS&Y valve supervisory switches detect the position of rising stem valves and report it to the fire alarm panel.
Details →
Preaction Systems
Preaction systems release water into the piping only after a detection signal, used where accidental discharge must be avoided.
Details →
Post Indicator
Post indicators allow underground fire line valves to be operated from above ground and show their position.
Details →
Test and Drain Valve
Test and drain valves allow flow testing and draining of sprinkler lines.
Details →
Waste Cone
Waste cones direct water from test and drain lines to the drain in a visible way.
Details →
Fire Check Valve
Fire check valves are approved check valves that prevent backflow in fire protection installations.
Details →
Fire Systems Pressure Reducing Valve
Fire systems pressure reducing valves lower excess pressure on lower floors of high-rise buildings to a suitable value for fire equipment.
Details →
Fire Sprinklers
Fire sprinklers open when the ambient temperature rises and automatically spray water onto the fire area.
Details →
Fire Valves
Fire valves are approved valves used to open and shut off lines in fire protection installations.
Details →
Above Ground Fire Hydrants
Above ground fire hydrants are outdoor hydrants that allow fire crews to draw water from the mains.
Details →
Grooved Pipe Fittings
Grooved pipe fittings allow fast assembly with couplings, without welding or threading, in fire and general installations.
Details →Get a quote for your project
Our sales team will prepare the best solution for your needs.
